CSoft.Protocol.FlueGasAnalyzer
11.0.3
dotnet add package CSoft.Protocol.FlueGasAnalyzer --version 11.0.3
NuGet\Install-Package CSoft.Protocol.FlueGasAnalyzer -Version 11.0.3
<PackageReference Include="CSoft.Protocol.FlueGasAnalyzer" Version="11.0.3" />
<PackageVersion Include="CSoft.Protocol.FlueGasAnalyzer" Version="11.0.3" />
<PackageReference Include="CSoft.Protocol.FlueGasAnalyzer" />
paket add CSoft.Protocol.FlueGasAnalyzer --version 11.0.3
#r "nuget: CSoft.Protocol.FlueGasAnalyzer, 11.0.3"
#:package CSoft.Protocol.FlueGasAnalyzer@11.0.3
#addin nuget:?package=CSoft.Protocol.FlueGasAnalyzer&version=11.0.3
#tool nuget:?package=CSoft.Protocol.FlueGasAnalyzer&version=11.0.3
CSoft.Protocol.FlueGasAnalyzer
杭州泽天春来烟气分析仪 v6.3 的 Modbus RTU 主站协议库。支持 netstandard2.0、net8.0、net9.0、net10.0 和 net11.0。
连接与读取
串口使用 8N1、无流控,支持 9600、38400 和 115200 波特率。示例中的串口、波特率和从站地址按仪表配置填写。
using CSoft.Protocol.FlueGasAnalyzer;
await using var analyzer = FlueGasAnalyzerClient.CreateSerial(
"COM3", baudRate: 9600, slaveAddress: 1, timeoutMilliseconds: 3000);
await analyzer.OpenAsync();
var identity = await analyzer.ReadIdentityAsync();
var values = await analyzer.ReadConcentrationsAsync();
if (identity.HasComponent(GasComponent.So2))
{
Console.WriteLine($"{identity.DeviceCode}: SO2 = {values.So2} mg/m³");
}
通过串口服务器连接时,使用 FlueGasAnalyzerClient.CreateRtuOverTcp(host, port)。网关须支持透传带 CRC 的 Modbus RTU 帧。
也可通过 new FlueGasAnalyzerClient(crowPort) 接入已有通讯口。端口须配置 Modbus RTU 解析器,由客户端独占请求调度,默认由调用方管理生命周期。
协议接口
| 接口 | 数据 |
|---|---|
ReadIdentityAsync |
24 字节 ASCII 设备编码、用户权限、组分及双量程位图 |
ReadConcentrationsAsync |
SO₂、NOx、O₂、NO、NO₂、CO、CO₂ 浓度和气室压力 |
ReadClockAsync、ReadInstrumentSettingsAsync |
仪表本地时间、反吹周期及持续时间、两路光强、NO/NOx 分子量模式 |
ReadStatusAsync、ReadAllStatusesAsync |
各组分的状态、故障及两组报警字 |
ReadCalibrationAsync、ReadAllCalibrationsAsync |
各组分的量程、校准系数、标气浓度、偏差、调零和标定时间、零点浓度 |
ReadSnapshotAsync |
多次读取组成的快照,指定 includeCalibration: true 时附带仪表已配置组分的校准参数 |
SetClockAsync |
一次写入年、月、日、时、分、秒,并校验响应回显 |
RegisterMap.Entries |
协议文档的 166 项寄存器定义,含零基线路地址、参考编号、类型、权限和单位 |
读取使用功能码 0x04,校时使用 0x10。校时参数按仪表当地时间传输,精度为秒,无时区转换。快照的 StartedAt 和 CompletedAt 表示客户端采集区间。
取消与重连
客户端串行发送请求。排队时可取消,已发送的请求会等到响应或超时再释放总线。取消无法撤回已发送的校时命令。
响应超时、响应帧错误或断线后,RequiresReconnect 会提示需要重新建立连接。成功调用 OpenAsync() 后可继续请求。
| Product | Versions Compatible and additional computed target framework versions. |
|---|---|
| .NET | net5.0 was computed. net5.0-windows was computed. net6.0 was computed. net6.0-android was computed. net6.0-ios was computed. net6.0-maccatalyst was computed. net6.0-macos was computed. net6.0-tvos was computed. net6.0-windows was computed. net7.0 was computed. net7.0-android was computed. net7.0-ios was computed. net7.0-maccatalyst was computed. net7.0-macos was computed. net7.0-tvos was computed. net7.0-windows was computed. net8.0 is compatible. net8.0-android was computed. net8.0-browser was computed. net8.0-ios was computed. net8.0-maccatalyst was computed. net8.0-macos was computed. net8.0-tvos was computed. net8.0-windows was computed. net9.0 is compatible. net9.0-android was computed. net9.0-browser was computed. net9.0-ios was computed. net9.0-maccatalyst was computed. net9.0-macos was computed. net9.0-tvos was computed. net9.0-windows was computed. net10.0 is compatible. net10.0-android was computed. net10.0-browser was computed. net10.0-ios was computed. net10.0-maccatalyst was computed. net10.0-macos was computed. net10.0-tvos was computed. net10.0-windows was computed. net11.0 is compatible. |
| .NET Core | netcoreapp2.0 was computed. netcoreapp2.1 was computed. netcoreapp2.2 was computed. netcoreapp3.0 was computed. netcoreapp3.1 was computed. |
| .NET Standard | netstandard2.0 is compatible. netstandard2.1 was computed. |
| .NET Framework | net461 was computed. net462 was computed. net463 was computed. net47 was computed. net471 was computed. net472 was computed. net48 was computed. net481 was computed. |
| MonoAndroid | monoandroid was computed. |
| MonoMac | monomac was computed. |
| MonoTouch | monotouch was computed. |
| Tizen | tizen40 was computed. tizen60 was computed. |
| Xamarin.iOS | xamarinios was computed. |
| Xamarin.Mac | xamarinmac was computed. |
| Xamarin.TVOS | xamarintvos was computed. |
| Xamarin.WatchOS | xamarinwatchos was computed. |
-
.NETStandard 2.0
- CSoft.Protocol.Modbus (>= 11.0.1)
- Microsoft.Bcl.AsyncInterfaces (>= 11.0.0)
- System.Memory (>= 4.6.3)
-
net10.0
- CSoft.Protocol.Modbus (>= 11.0.1)
-
net11.0
- CSoft.Protocol.Modbus (>= 11.0.1)
-
net8.0
- CSoft.Protocol.Modbus (>= 11.0.1)
-
net9.0
- CSoft.Protocol.Modbus (>= 11.0.1)
NuGet packages
This package is not used by any NuGet packages.
GitHub repositories
This package is not used by any popular GitHub repositories.
| Version | Downloads | Last Updated |
|---|---|---|
| 11.0.3 | 42 | 11/19/2026 |
| 11.0.2 | 104 | 11/13/2026 |
| 11.0.1 | 84 | 11/13/2026 |
| 11.0.0 | 94 | 11/13/2026 |
| 10.1.0 | 140 | 8/21/2026 |
| 10.0.11 | 173 | 1/14/2026 |
| 10.0.10 | 143 | 1/14/2026 |
| 10.0.9 | 146 | 1/13/2026 |
| 10.0.8 | 144 | 1/13/2026 |
| 10.0.7 | 151 | 1/13/2026 |
| 10.0.6 | 151 | 1/9/2026 |
| 10.0.5 | 199 | 12/26/2025 |
| 10.0.3 | 223 | 12/23/2025 |
| 10.0.2 | 319 | 12/18/2025 |
| 10.0.1 | 317 | 12/18/2025 |
| 10.0.0 | 318 | 12/17/2025 |